Security hardening: CORS lockdown, rate limiting middleware con sliding window e eviction IP stale, security headers (CSP, HSTS, X-Frame-Options), session cookie hardening, filename sanitization upload. i18n completion: internazionalizzati barcode.js e csv-export.js con bridge window.BARCODE_I18N/CSV_I18N, aggiornati .po IT/EN con 27 nuove stringhe. Tablet UX: touch target 44px per dispositivi coarse pointer. Test suite: 101 test totali (76 server + 25 client), copertura completa di tutti i router API, autenticazione, ruoli, CRUD, SPC, file upload, security integration. Infrastruttura SQLite async in-memory con fixtures. Fix critici: MissingGreenlet in recipe_service (selectinload eager), route ordering tasks.py, auth_service bcrypt diretto, Measurement.id Integer per SQLite. Documentazione: API.md (riferimento completo 40+ endpoint), DEPLOYMENT.md (guida produzione con Docker/Nginx/SSL), USER_GUIDE.md (manuale utente per ruolo). Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
694 lines
20 KiB
Markdown
694 lines
20 KiB
Markdown
# TieMeasureFlow User Guide
|
|
|
|
Welcome to TieMeasureFlow - a comprehensive measurement task management system designed for precision measurement workflows with caliper measurements, barcode tracking, and statistical process control.
|
|
|
|
## Table of Contents
|
|
|
|
1. [System Overview](#system-overview)
|
|
2. [Getting Started](#getting-started)
|
|
3. [User Roles](#user-roles)
|
|
4. [Maker Workflow](#maker-workflow)
|
|
5. [MeasurementTec Workflow](#measurementtec-workflow)
|
|
6. [Metrologist Workflow](#metrologist-workflow)
|
|
7. [Admin Workflow](#admin-workflow)
|
|
8. [UI Features](#ui-features)
|
|
9. [Keyboard Shortcuts](#keyboard-shortcuts)
|
|
10. [Tips & Tricks](#tips--tricks)
|
|
|
|
## System Overview
|
|
|
|
### What is TieMeasureFlow?
|
|
|
|
TieMeasureFlow is a web-based measurement management system that enables teams to:
|
|
|
|
- **Create measurement recipes** - Define measurement procedures with tasks, subtasks, and tolerance specifications
|
|
- **Execute measurements** - Record measurements using USB calipers or manual input with automatic pass/fail determination
|
|
- **Track traceability** - Associate measurements with lot numbers, serial numbers, and operators
|
|
- **Analyze quality** - Generate SPC (Statistical Process Control) charts, capability indices, and quality reports
|
|
- **Export data** - Download measurements as CSV or generate PDF reports with configurable formatting
|
|
|
|
### Key Concepts
|
|
|
|
| Concept | Description |
|
|
|---------|-------------|
|
|
| **Recipe** | Master document that defines a set of measurements to perform |
|
|
| **Version** | Immutable snapshot of a recipe. Editing creates a new version; old measurements stay linked to original |
|
|
| **Task** | Logical group of related subtasks (e.g., "Measure external dimensions") |
|
|
| **Subtask** | Individual measurement point with tolerance limits (UTL/UWL/LWL/LTL) |
|
|
| **Measurement** | Individual recorded value with automatic pass/fail/warning status |
|
|
| **Lot/Serial** | Traceability fields linking measurements to physical parts |
|
|
|
|
### Architecture
|
|
|
|
```
|
|
TieMeasureFlow
|
|
├── Server (FastAPI on port 8000)
|
|
│ ├── Authentication & Authorization
|
|
│ ├── Recipe versioning & management
|
|
│ ├── Measurement storage & analysis
|
|
│ └── Statistical calculations
|
|
└── Client (Flask on port 5000)
|
|
├── Maker: Recipe editor
|
|
├── MeasurementTec: Measurement entry
|
|
├── Metrologist: SPC dashboard
|
|
└── Admin: User management
|
|
```
|
|
|
|
---
|
|
|
|
## Getting Started
|
|
|
|
### Login
|
|
|
|
1. Open `http://localhost:5000` (or your configured client URL)
|
|
2. Enter **username** and **password**
|
|
3. Click **Login**
|
|
|
|
You are now logged in and redirected to your role's dashboard.
|
|
|
|
### Change Language
|
|
|
|
Click the **language selector** (top-right) to switch between:
|
|
- **Italian (Italiano)** - Default
|
|
- **English** - Full UI and data labels translated
|
|
|
|
Language preference is saved to your profile.
|
|
|
|
### Change Theme
|
|
|
|
Click the **theme toggle** (sun/moon icon, top-right) to switch between:
|
|
- **Light Mode** - White background, dark text
|
|
- **Dark Mode** - Dark background, light text
|
|
|
|
Theme preference is saved to your profile.
|
|
|
|
### Profile Settings
|
|
|
|
1. Click your **username** (top-right)
|
|
2. Select **Profile** or **Settings**
|
|
3. Update:
|
|
- Display name
|
|
- Email
|
|
- Language preference
|
|
- Theme preference
|
|
4. Click **Save**
|
|
|
|
---
|
|
|
|
## User Roles
|
|
|
|
TieMeasureFlow has four primary roles. Users can have multiple roles simultaneously.
|
|
|
|
### Maker
|
|
|
|
**Purpose:** Create and maintain measurement procedures
|
|
|
|
**Permissions:**
|
|
- Create new recipes
|
|
- Edit recipe structure (tasks, subtasks, tolerances)
|
|
- Add measurement points and annotations
|
|
- Upload images/PDFs for reference
|
|
- View recipe history and versions
|
|
- Manage recipe access
|
|
|
|
**Access:**
|
|
- Menu: **Maker** → Recipe Management
|
|
- Can see: All recipes and their versions
|
|
|
|
**Typical Tasks:**
|
|
- Define new measurement procedures
|
|
- Set tolerance limits (UTL/UWL/LWL/LTL)
|
|
- Create visual annotations on images
|
|
- Document measurement instructions
|
|
|
|
---
|
|
|
|
### MeasurementTec
|
|
|
|
**Purpose:** Execute measurements in the field/lab
|
|
|
|
**Permissions:**
|
|
- Select recipes to measure
|
|
- Record individual measurements
|
|
- Use USB caliper for automated input
|
|
- Scan barcodes for lot/serial tracking
|
|
- View assigned measurement tasks
|
|
- Export measurements to CSV
|
|
|
|
**Access:**
|
|
- Menu: **Measure** → Task Execution
|
|
- Can see: Published recipes only
|
|
|
|
**Typical Tasks:**
|
|
- Open a recipe via barcode or search
|
|
- Follow task instructions
|
|
- Record measurements (manual or USB caliper)
|
|
- Scan lot and serial numbers
|
|
- Monitor real-time pass/fail status
|
|
|
|
---
|
|
|
|
### Metrologist
|
|
|
|
**Purpose:** Analyze measurements and generate quality reports
|
|
|
|
**Permissions:**
|
|
- View all measurements across recipes
|
|
- Access SPC statistics and control charts
|
|
- View capability indices (Cp, Cpk, Pp, Ppk)
|
|
- Generate PDF reports
|
|
- Export measurements and charts
|
|
- Filter data by recipe, date, operator, lot
|
|
|
|
**Access:**
|
|
- Menu: **Statistics** → SPC Dashboard
|
|
- Can see: All measurements and statistics
|
|
|
|
**Typical Tasks:**
|
|
- Monitor process capability
|
|
- Generate control charts
|
|
- Investigate out-of-control conditions
|
|
- Export data for analysis
|
|
- Create quality reports
|
|
|
|
---
|
|
|
|
### Admin
|
|
|
|
**Purpose:** System administration and user management
|
|
|
|
**Permissions:**
|
|
- Create/edit/delete users
|
|
- Assign roles to users
|
|
- Regenerate user API keys
|
|
- Configure system settings
|
|
- Upload company logo
|
|
- Manage CSV export settings
|
|
|
|
**Access:**
|
|
- Menu: **Admin** → User Management
|
|
- Can see: All users and system settings
|
|
|
|
**Typical Tasks:**
|
|
- Onboard new users
|
|
- Reset lost API keys
|
|
- Configure locale/format settings
|
|
- Upload company branding
|
|
- Manage system access
|
|
|
|
---
|
|
|
|
## Maker Workflow
|
|
|
|
### Create a New Recipe
|
|
|
|
1. Navigate to **Maker** → **Recipe Management**
|
|
2. Click **New Recipe**
|
|
3. Enter details:
|
|
- **Code**: Unique identifier (e.g., `RECIPE_MOTOR_001`)
|
|
- **Name**: Human-readable name
|
|
- **Description**: Purpose and context
|
|
4. Click **Create Recipe**
|
|
5. Recipe v1 is created and ready for editing
|
|
|
|
### Add Tasks and Subtasks
|
|
|
|
1. Open a recipe
|
|
2. Click **Add Task**
|
|
3. Enter task details:
|
|
- **Title**: e.g., "Measure external dimensions"
|
|
- **Directive**: Step-by-step instructions
|
|
- **Description**: Additional context
|
|
- **File Type**: Select if using images/PDFs
|
|
4. Click **Add Subtask** for each measurement point
|
|
5. For each subtask:
|
|
- **Marker #**: Unique number within task (e.g., 1, 2, 3)
|
|
- **Description**: What is being measured
|
|
- **Measurement Type**: `length`, `angle`, `diameter`, etc.
|
|
- **Nominal**: Target value
|
|
- **UTL**: Upper Tolerance Limit (hard limit)
|
|
- **UWL**: Upper Warning Limit (warning zone)
|
|
- **LWL**: Lower Warning Limit (warning zone)
|
|
- **LTL**: Lower Tolerance Limit (hard limit)
|
|
- **Unit**: `mm`, `inch`, `degree`, etc.
|
|
|
|
**Tolerance Example:**
|
|
```
|
|
LTL: 9.5 mm (FAIL below this)
|
|
LWL: 9.8 mm (WARNING below this)
|
|
Nominal: 10.0 mm
|
|
UWL: 10.2 mm (WARNING above this)
|
|
UTL: 10.5 mm (FAIL above this)
|
|
```
|
|
|
|
### Add Annotations & Images
|
|
|
|
1. Open a task
|
|
2. Click **Upload Image** to add reference photo
|
|
3. Click **Annotate** to add visual markers
|
|
4. In the annotation editor:
|
|
- **Marker Tool**: Click to place numbered points
|
|
- **Text Tool**: Add labels
|
|
- **Draw Tool**: Add circles/lines
|
|
5. Save annotations
|
|
|
|
### Manage Versions
|
|
|
|
When you edit a recipe (add/remove tasks, change tolerances), a **new version** is created automatically. This ensures:
|
|
|
|
- Measurements remain linked to the version they were recorded against
|
|
- You can compare results across versions
|
|
- Historical record is preserved
|
|
|
|
**Version Management:**
|
|
1. Open recipe
|
|
2. Click **Versions** tab
|
|
3. View all versions with:
|
|
- Version number and date
|
|
- Who made changes
|
|
- Change notes
|
|
- Measurement count
|
|
4. Click version to view its structure
|
|
|
|
**Warning:** If a version has existing measurements, you cannot edit it directly. Create a new version to make changes.
|
|
|
|
---
|
|
|
|
## MeasurementTec Workflow
|
|
|
|
### Select a Recipe
|
|
|
|
**Method 1: Search**
|
|
1. Navigate to **Measure** → **Select Recipe**
|
|
2. Type recipe name or code in search box
|
|
3. Click recipe from results
|
|
|
|
**Method 2: Barcode Scan**
|
|
1. Navigate to **Measure** → **Select Recipe**
|
|
2. Scan recipe barcode
|
|
3. Recipe loads automatically
|
|
|
|
### Enter Lot & Serial Information
|
|
|
|
After selecting recipe:
|
|
1. **Lot Number**: Scan or type batch identifier
|
|
2. **Serial Number**: Scan or type part identifier
|
|
3. Click **Continue**
|
|
|
|
This information is recorded with every measurement for traceability.
|
|
|
|
### Perform Measurements
|
|
|
|
For each task:
|
|
|
|
1. **Read Instructions** - Display shows task directive and reference image
|
|
2. **Locate Measurement Points** - Find marked positions on the part
|
|
3. **Record Measurement**:
|
|
|
|
**Option A: USB Caliper**
|
|
- Connect USB caliper to tablet/computer
|
|
- Place part in caliper
|
|
- Press measurement button on caliper
|
|
- System automatically records value
|
|
- Move to next measurement point
|
|
|
|
**Option B: Manual Entry**
|
|
- Type measured value in input field
|
|
- Value field accepts decimals and negative numbers
|
|
- Press Enter or click Next
|
|
|
|
4. **Monitor Pass/Fail Status**:
|
|
- **GREEN/Pass**: Value within LWL-UWL
|
|
- **YELLOW/Warning**: Value within LTL-LWL or UWL-UTL
|
|
- **RED/Fail**: Value outside LTL or UTL
|
|
|
|
5. **Submit Measurements** - Click Submit when all tasks complete
|
|
|
|
### Keyboard Shortcuts
|
|
|
|
| Shortcut | Action |
|
|
|----------|--------|
|
|
| `Tab` | Move to next measurement field |
|
|
| `Shift+Tab` | Move to previous field |
|
|
| `Enter` | Submit measurement and move to next |
|
|
| `Esc` | Cancel current task |
|
|
| `Ctrl+Z` | Undo last measurement |
|
|
|
|
### USB Caliper Auto-Detection
|
|
|
|
TieMeasureFlow automatically detects USB caliper input. To use:
|
|
|
|
1. Connect caliper via USB
|
|
2. Open measurement form
|
|
3. Focus on measurement input field
|
|
4. Press measurement button on caliper
|
|
5. Value appears in field automatically
|
|
|
|
**Note:** System distinguishes caliper input (rapid <30ms intervals, 3+ keystrokes) from human typing (>100ms intervals).
|
|
|
|
---
|
|
|
|
## Metrologist Workflow
|
|
|
|
### Access SPC Dashboard
|
|
|
|
1. Navigate to **Statistics** → **SPC Dashboard**
|
|
2. Dashboard loads with recipe list
|
|
|
|
### Select Data to Analyze
|
|
|
|
1. **Recipe**: Select from dropdown (required)
|
|
2. **Version**: Leave blank for all versions, or select specific version
|
|
3. **Subtask**: Select specific measurement point, or leave blank for summary
|
|
4. **Date Range**: Optional - filter by measurement date
|
|
5. **Operator**: Optional - filter by who performed measurement
|
|
6. **Lot/Serial**: Optional - filter by part traceability
|
|
|
|
Click **Apply Filters**
|
|
|
|
### View Summary Statistics
|
|
|
|
Card displays:
|
|
- **Total Measurements**: Count
|
|
- **Pass %**: Percentage passing all limits
|
|
- **Warning %**: Percentage in warning zone
|
|
- **Fail %**: Percentage outside limits
|
|
|
|
Use for quick quality assessment.
|
|
|
|
### Analyze Control Chart
|
|
|
|
The **control chart** displays:
|
|
|
|
- **Individual Points**: Each measurement value
|
|
- **Center Line**: Mean (average) value
|
|
- **UCL/LCL**: Upper/Lower Control Limits
|
|
- **Red Markers**: Out-of-control points
|
|
|
|
**What to Look For:**
|
|
- Points outside UCL or LCL → Process out of control
|
|
- Trend (6+ consecutive rising/falling) → Process drift
|
|
- All points on one side of center → Bias
|
|
- Regular oscillation → Calibration problem
|
|
|
|
### Check Process Capability
|
|
|
|
**Capability Indices** tell you if the process can consistently meet specifications:
|
|
|
|
| Index | What It Means | Target |
|
|
|-------|---------------|--------|
|
|
| **Cp** | Process capability (theoretical) | > 1.33 |
|
|
| **Cpk** | Process capability (actual, accounting for centering) | > 1.33 |
|
|
| **Pp** | Process performance (single sample) | > 1.67 |
|
|
| **Ppk** | Process performance (accounting for centering) | > 1.67 |
|
|
|
|
**Interpretation:**
|
|
- **Cpk > 1.67**: Excellent - process is capable
|
|
- **Cpk 1.33-1.67**: Good - process is acceptable
|
|
- **Cpk < 1.33**: Poor - process needs improvement
|
|
|
|
### View Histogram
|
|
|
|
The **histogram** shows:
|
|
|
|
- **Bars**: Distribution of measured values across bins
|
|
- **Curve**: Theoretical normal distribution overlay
|
|
- **Limits**: Vertical lines for LTL/LWL/UWL/UTL
|
|
|
|
**What to Look For:**
|
|
- Normal bell curve → Process is well-behaved
|
|
- Bimodal (two peaks) → Two different populations mixing
|
|
- Skewed distribution → Process bias
|
|
- Values outside limits → Specification violations
|
|
|
|
### Generate Reports
|
|
|
|
#### SPC Report (PDF)
|
|
|
|
1. Select filters (recipe, subtask, date range)
|
|
2. Click **Export SPC Report**
|
|
3. PDF downloads with:
|
|
- Control chart graph
|
|
- Histogram with curve
|
|
- Capability statistics
|
|
- Summary table
|
|
|
|
#### Measurements Report (PDF)
|
|
|
|
1. Select filters (optional subtask filter)
|
|
2. Click **Export Measurements Report**
|
|
3. PDF downloads with:
|
|
- Complete measurement table
|
|
- Pass/fail status
|
|
- Lot/serial information
|
|
- Operator name and date
|
|
|
|
#### CSV Export
|
|
|
|
1. Click **Export Data** button
|
|
2. CSV downloads with all filtered measurements
|
|
3. Columns: ID, subtask, version, operator, value, pass/fail, deviation, lot, serial, date
|
|
4. Delimiter and decimal format per system settings
|
|
|
|
---
|
|
|
|
## Admin Workflow
|
|
|
|
### User Management
|
|
|
|
#### Create User
|
|
|
|
1. Navigate to **Admin** → **User Management**
|
|
2. Click **Add User**
|
|
3. Enter:
|
|
- **Username**: Login identifier (must be unique)
|
|
- **Password**: Initial password (user can change after login)
|
|
- **Display Name**: Full name for display
|
|
- **Email**: Contact email
|
|
- **Roles**: Check one or more:
|
|
- Maker
|
|
- MeasurementTec
|
|
- Metrologist
|
|
- **Admin**: Check if user manages other users
|
|
4. Click **Create User**
|
|
5. Confirm user was created and notify them to change password
|
|
|
|
#### Edit User
|
|
|
|
1. Navigate to **Admin** → **User Management**
|
|
2. Click user row to edit
|
|
3. Update fields (all optional):
|
|
- Display name
|
|
- Email
|
|
- Roles
|
|
- Admin status
|
|
- Active status
|
|
4. Click **Save**
|
|
|
|
#### Deactivate User
|
|
|
|
1. Navigate to **Admin** → **User Management**
|
|
2. Click user row
|
|
3. Click **Deactivate User**
|
|
4. Confirm - user is soft-deleted (can be reactivated)
|
|
5. User's API key is cleared, login no longer works
|
|
|
|
#### Reset API Key
|
|
|
|
If user loses their API key:
|
|
|
|
1. Navigate to **Admin** → **User Management**
|
|
2. Click user row
|
|
3. Click **Regenerate API Key**
|
|
4. New key is generated and displayed
|
|
5. Provide new key to user (display once only)
|
|
|
|
### System Settings
|
|
|
|
#### Configure CSV Export
|
|
|
|
1. Navigate to **Admin** → **Settings**
|
|
2. Update:
|
|
- **CSV Delimiter**: `,` (comma) or `;` (semicolon)
|
|
- **CSV Decimal Separator**: `.` (period) or `,` (comma)
|
|
3. Click **Save**
|
|
4. All future CSV exports use these settings
|
|
|
|
**Example:**
|
|
- European format: Delimiter `;`, Decimal `,`
|
|
- US/UK format: Delimiter `,`, Decimal `.`
|
|
|
|
#### Upload Company Logo
|
|
|
|
1. Navigate to **Admin** → **Settings**
|
|
2. Click **Upload Logo**
|
|
3. Select image file (JPEG, PNG, GIF, WebP, SVG, max 50 MB)
|
|
4. Click **Upload**
|
|
5. Logo appears in header of all pages
|
|
|
|
---
|
|
|
|
## UI Features
|
|
|
|
### Navigation
|
|
|
|
**Top Navigation Bar:**
|
|
- Logo/company branding (left)
|
|
- Main menu: Measure, Maker, Statistics, Admin (center)
|
|
- Language selector, Theme toggle, User menu (right)
|
|
|
|
**Breadcrumbs:** Show current page hierarchy
|
|
|
|
**Search:** Available on list pages to filter by name/code
|
|
|
|
### Responsive Design
|
|
|
|
- **Desktop (1024px+)**: Full layout with sidebar
|
|
- **Tablet (768px+)**: Sidebar collapses to hamburger menu
|
|
- **Mobile (< 768px)**: Touch-optimized layout
|
|
|
|
### Data Tables
|
|
|
|
- **Sortable columns**: Click header to sort ascending/descending
|
|
- **Pagination**: Navigate between pages
|
|
- **Filters**: Narrow results by multiple criteria
|
|
- **Export**: Download as CSV
|
|
|
|
### Forms
|
|
|
|
- **Auto-save**: Some fields auto-save when you leave the field
|
|
- **Validation**: Error messages shown inline
|
|
- **Tooltips**: Hover over `?` icons for field help
|
|
- **Progress indicators**: Multi-step forms show progress
|
|
|
|
### Modal Dialogs
|
|
|
|
- Confirmation for destructive actions
|
|
- Forms for data entry
|
|
- Information displays
|
|
- Close with X button or Cancel
|
|
|
|
---
|
|
|
|
## Tips & Tricks
|
|
|
|
### Maker Best Practices
|
|
|
|
1. **Use Clear Naming**: Task and subtask names should describe exactly what is measured
|
|
2. **Document Units**: Always specify units (mm, inches, degrees) in subtask description
|
|
3. **Set Realistic Tolerances**: Ensure UTL/LTL are achievable with your equipment
|
|
4. **Version Control**: Add meaningful change notes when creating new versions
|
|
5. **Use Annotations**: Visual markers help operators find exact measurement points
|
|
6. **Test First**: Do a test measurement before rollout to ensure tolerances are reasonable
|
|
|
|
### MeasurementTec Best Practices
|
|
|
|
1. **Barcode Scanning**: Scan lot/serial barcodes rather than typing to avoid errors
|
|
2. **Consistent Operator**: Use consistent technique - caliper orientation, pressure, etc.
|
|
3. **Check Zero**: Zero your caliper at start of shift
|
|
4. **Monitor Warnings**: Watch for warning zone measurements - may indicate drift
|
|
5. **Document Deviations**: If you encounter fails, note the cause in observations
|
|
6. **Batch Together**: Group measurements from same lot for statistical significance
|
|
|
|
### Metrologist Best Practices
|
|
|
|
1. **Regular Reviews**: Check control charts daily for out-of-control conditions
|
|
2. **Trend Analysis**: Look beyond individual points - watch for sustained trends
|
|
3. **Root Cause**: When investigating failures, cross-reference by operator and time
|
|
4. **Baseline**: Establish baseline capability when process starts
|
|
5. **Update Limits**: Periodically review if specification limits are appropriate
|
|
6. **Archive Reports**: Keep dated PDF reports for audit trail
|
|
|
|
### Performance Tips
|
|
|
|
1. **Filter Early**: Use date range and version filters to speed up statistics queries
|
|
2. **Batch Operations**: Enter multiple measurements at once rather than one-by-one
|
|
3. **Cache Data**: Browser caches filter selections - reuse recent filters
|
|
4. **Offline Mode**: Some tablet deployments support offline measurement entry, synced later
|
|
5. **Export Over Display**: For large datasets (>1000 measurements), export to CSV and analyze in Excel
|
|
|
|
### Troubleshooting
|
|
|
|
**"Recipe not found" when scanning barcode**
|
|
- Verify barcode matches recipe code
|
|
- Check recipe is active (not deactivated)
|
|
- Try searching by name instead
|
|
|
|
**USB Caliper not working**
|
|
- Check USB cable connection
|
|
- Try removing and re-inserting caliper
|
|
- Check browser console for permission errors
|
|
- Use manual entry as backup
|
|
|
|
**Measurements seem wrong**
|
|
- Verify subtask is correct marker number
|
|
- Check caliper zero before starting
|
|
- Look for outliers - may indicate operator error
|
|
- Export data and check in spreadsheet
|
|
|
|
**Cannot edit recipe**
|
|
- Recipe may have existing measurements
|
|
- Create new version first
|
|
- Check if you have Maker role
|
|
|
|
**Export file encoding issues**
|
|
- If Excel shows garbled characters, check CSV settings
|
|
- Try semicolon delimiter with comma decimal separator for European locales
|
|
- File is UTF-8 encoded; ensure Excel opens with UTF-8 encoding
|
|
|
|
---
|
|
|
|
## Getting Help
|
|
|
|
### Online Resources
|
|
|
|
- **API Documentation**: `http://localhost:8000/docs`
|
|
- **Project Guide**: See `DEPLOYMENT.md` and `API.md`
|
|
- **Database Structure**: See schema in Alembic migrations
|
|
|
|
### Contact Support
|
|
|
|
- **System Admin**: For user account issues
|
|
- **Maker Manager**: For recipe structure and tolerance questions
|
|
- **Quality Engineer**: For SPC interpretation and reporting
|
|
|
|
---
|
|
|
|
## Keyboard & Accessibility
|
|
|
|
### Keyboard Navigation
|
|
|
|
- `Tab`: Navigate between fields
|
|
- `Shift+Tab`: Navigate backwards
|
|
- `Enter`: Submit forms
|
|
- `Escape`: Close modals/cancel operations
|
|
- `Alt+M`: Jump to main menu
|
|
- `Alt+S`: Jump to search
|
|
|
|
### Screen Reader Support
|
|
|
|
- All UI elements have proper ARIA labels
|
|
- Forms announce validation errors
|
|
- Tables have accessible headers
|
|
- Images have alt text
|
|
|
|
### High Contrast Mode
|
|
|
|
Enabled automatically for operating systems with high contrast settings
|
|
|
|
---
|
|
|
|
## Version History
|
|
|
|
**TieMeasureFlow v0.1.0**
|
|
|
|
Released: February 2025
|
|
|
|
**Features:**
|
|
- Recipe versioning with copy-on-write
|
|
- USB caliper integration
|
|
- SPC statistics and control charts
|
|
- PDF report generation
|
|
- Multi-language support (IT/EN)
|
|
- Light/Dark theme
|